VAPAWAY.EU - Research and education on VAP prevention
  • Home
  • Articles
  • GuideLines
  • Links
  • About VAPAWAY
  • Training
  • Contacts

Login








Lost Password?

Register to receive updated data on VAPAWAY initiative

Agenda

 

9 - 12 March 2010

ISICEM International Symposium on Intensive Care and Emergency Medicine - Brussels (Belgium)

ISICEM

 

9 -11 June 2010

EACTA European Association of Cardiothoracic Anaesthesiologists - Edinburgh (UK)

EACTA

 

12-15 June 2010

ESA European Society of Anaesthesiology - Helsinki (Finland)

ESA

 

18-22 September 2010

ERS European Respiratory Society - Barcellona (Spain)

ERS

 

9 -13 October 2010

ESICM European Society of Intensive Care Medicine - Barcellona (Spain)

ESICM

  

 

> International events   

> Local events 

PDF Print E-mail
Monday, 28 April 2008

Jackson SR, Ernst NE, Mueller EW, Butler KL., Department of Surgery, University of Cincinnati, OH, USA, Am J Surg. 2008 Feb;195(2):159-63


 

BACKGROUND: Bronchoalveolar lavage (BAL) is recommended to facilitate the diagnosis of ventilator-associated pneumonia (VAP). It is unclear if bilateral sampling improves the accuracy of BAL.

METHODS: Consecutive patients with clinical suspicion for VAP were analyzed. All patients underwent bilateral BAL. A threshold of >10(4) colony-forming units (cfu)/mL was diagnostic for VAP (VAP positive). Samples were concordant if the organism(s) and thresholds from both lungs were diagnostically consistent. Organisms </=10(4) cfu/mL with growth on the contralateral sample >10(4) cfu/mL were considered false-negative samples.

RESULTS: Between November 2005 and April 2006, 73 patients were considered clinically suspicious for VAP. Forty-four (60%) patients were VAP positive. Twenty-eight (64%) VAP patients had concordant samples. Overall, there were 15 false-negative samples. Sole use of the unilateral samples to guide treatment would have inappropriately directed antibiotic avoidance and/or discontinuation in 25% of VAP patients. Influence of the chest radiograph was equivocal because of the presence of bilateral infiltrates in 80% of discordant samples.

CONCLUSIONS: Bilateral BAL improves the accuracy of bronchoscopy in diagnosing VAP. Unilateral BAL may be insensitive in patients with clinically significant contralateral infection.

Last Updated ( Monday, 28 April 2008 )
 
< Prev   Next >
Select and watch
from the following webinars

 


Join us on www.smartonweb.org

Partner

VAPAWAY is proudly supported by Covidien.

http://www.covidien.com