Login
Agenda
9 - 12 March 2010
ISICEM International Symposium on Intensive Care and Emergency Medicine - Brussels (Belgium)
9 -11 June 2010
EACTA European Association of Cardiothoracic Anaesthesiologists - Edinburgh (UK)
12-15 June 2010
ESA European Society of Anaesthesiology - Helsinki (Finland)
18-22 September 2010
ERS European Respiratory Society - Barcellona (Spain)
9 -13 October 2010
ESICM European Society of Intensive Care Medicine - Barcellona (Spain)
> International events
| PLASMA CC16 LEVELS ARE ASSOCIATED WITH DEVELOPMENT OF ALI/ARDS IN PATIENTS WITH VAP: A RETROSPECTIVE |
|
|
|
| Friday, 29 January 2010 | |
|
Determann RM, Millo JL, Waddy S, Lutter R, Garrard CS, Schultz MJ.
Department of Intensive Care Medicine, Academic Medical Center, Amsterdam, The Netherlands.
BMC Pulm Med. 2009 Dec 3;9:49.
BACKGROUND: Despite consensus criteria, diagnosing acute lung injury, or its more severe form acute respiratory distress syndrome (ALI/ARDS) remains challenging. Adding objective measures, such as plasma levels of biological markers could facilitate recognition of ALI/ARDS. This study was designed to assess and compare the diagnostic accuracy of biological markers for ALI/ARDS with ventilator-associated pneumonia (VAP). METHODS: We performed serial measurements of Clara cell protein (CC16), soluble receptor for advanced glycation end products (sRAGE), surfactant protein D (SP-D) and Krebs von den Lungen (KL-6) in plasma of patients with VAP and mechanically ventilated control patients without VAP. ALI/ARDS was diagnosed using the criteria of the North-American European consensus conference. RESULTS: Thirty-seven patients were enrolled - 22 patients with VAP and 15 control patients. Ten patients with pneumonia met the ALI/ARDS consensus criteria. Control patients never met these criteria. Plasma CC16 had a good diagnostic capacity for ALI/ARDS as shown by the receiver operating characteristic curve with an area under the curve of 0.91 (95% confidence interval (CI) 0.79 - 1.00; p < 0.001). Identification of ALI/ARDS patients by sudden increases in plasma CC16 of 30% or more yielded a sensitivity of 90% and a specificity of 92%. Of note, levels of CC16 increased 2 days before ALI/ARDS diagnosis. A cut-off level of 50 ng/ml SP-D yielded a specificity of 100% while the sensitivity was 70%. The area under the curve for SP-D was 0.80 (95% CI 0.58 - 1.00; p = 0.02). The diagnostic accuracies of KL-6 and sRAGE were low. CONCLUSION: Plasma CC16 seems a potential biological marker for ALI/ARDS in patients with VAP. Plasma levels of sRAGE, SP-D and KL-6 have limited discriminative power for diagnosing ALI/ARDS in VAP.
|
| < Prev | Next > |
|---|
![]() |
| Select and watch from the following webinars |












